List of certificates by Products


IEEE Std C37.09 - Circuit-Breakers

Category: Gas


Voltage
Continuous current
Frequency
Short-circuit current
Minimum opening time
Arc extinguishing medium
Closing mechanism
Designation
Certification number
Cert. Type
Contents
Remarks
Owner
72.5 3150 50/60 40 - SF6 Stored energy closing (springs) LW24-72.5 2163-13 D abcr Additional capacitance was connected during L75 test (60 Hz) and L90 (50 Hz and 60 Hz) test only. XIAN XD-HV
72.5 3150 50/60 40 - SF6 Stored energy closing (springs) LW24-72.5 2164-13 D abcr Tests based on 40 kA. XIAN XD-HV
72.5 3150 50/60 40 - SF6 Stored energy closing (springs) LW24-72.5 2167-13 E ef Additional capacitance was connected during L75 test (60 Hz) and L90 (50 Hz and 60 Hz) test only. XIAN XD-HV
72.5 3150 50/60 40 - SF6 Stored energy closing (springs) LW24-72.5 2168-13 E ef Tests based on 40 kA. XIAN XD-HV
38 1250 60 40 Stored energy closing (springs, charged by motor) VD4X 3812-40 2360-15 D a ABB-DERA
145 3150 50/60 40 SF6 Stored energy closing (springs) CB145-I 2148-13 D a,b,c XIAN XD-CNX
145 3150 50/60 40 SF6 Stored energy closing (springs) CB145-I 2150-13 E e,f XIAN XD-CNX
145 3150 50/60 31.5 SF6 Stored energy closing (springs) CB145-I 2170-13 D a,b,c XIAN XD-CNX
145 3150 50/60 31.5 SF6 LW24-145 2105-14 D a,b,c XIAN XD-HV
38 2000 60 31.5 16.7 Stored energy closing (springs, charged by motor) TKDV-38 2332-17 H a SHANDONGTAIKAI-CNT
38 2000 60 31.5 16.7 Stored energy closing (springs, charged by motor) TKDV-38 2332-17 E e,f SHANDONGTAIKAI-CNT
252 4000 60 50 22.5 SF6 Stored energy closing (springs, charged by motor) LW24-252/T4000-50 2114-18 E e,f XIAN XD-CNX
252 4000 60 50 22.5 SF6 Stored energy closing (springs, charged by motor) LW24-252/T4000-50 2128-18 E e,f XIAN XD-CNX
145 3150 50/60 40 3 SF6 Stored energy closing (springs, charged by motor) HCSP144D1 2113-19 D a,b,c HYOSUNG
145 3150 50/60 40 - SF6 Stored energy closing (springs, charged by motor) HCSP144D1 2114-19 E e,f,g,h HYOSUNG
145 3150 50/60 40 - SF6 Stored energy closing (springs, charged by motor) HCSP144D1 2115-19 E w HYOSUNG
40.5 630 60 25 41 SF6 Stored energy closing (springs, charged by motor) VG6-S - SafePlus 36 V-Panel Mk2 2486-19 D,E a ABB-NOS
17.5 2000 50/60 40 26 vacuum Stored energy closing (springs, charged by motor) LGO174020G15B 2419-21 D abc SCHNEIDER-USS


Category: Vacuum


Voltage
Continuous current
Frequency
Short-circuit current
Minimum opening time
Arc extinguishing medium
Closing mechanism
Designation
Certification number
Cert. Type
Contents
Remarks
Owner
17.5 1250 50/60 31.5 20 vacuum Stored energy closing (springs, charged by motor) TCB 17-31-12 2325-15 D a TGOOD
17.5 3150 60 31.5 17.1 vacuum Stored energy closing (springs, charged by motor) TCB 17-31-31 2330-15 D a TGOOD
38 2000 60 31.5 28.9 vacuum Stored energy closing (springs, charged by motor) AH12 2142-20 D,E a ABB SACE
38 1250 50/60 40 30 SF6 Stored energy closing (springs, charged by motor) Power Xpert IGX Gas Insulated Switchgear 2046-20 D a,b Eaton_USA
38 1250 50/60 40 30 SF6 Stored energy closing (springs, charged by motor) Power Xpert IGX Gas Insulated Switchgear 2047-20 E f Eaton_USA
38 1250 50/60 40 30 SF6 Stored energy closing (springs, charged by motor) Power Xpert IGX Gas Insulated Switchgear 2048-20 E h Eaton_USA


An error has occurred. This application may no longer respond until reloaded. Reload X